ZW32 sab nraum zoov ncej mounted pib recloser

Lus piav qhia luv luv:


Product Detail

Khoom cim npe

Kev piav qhia

ZW32 Auto recloser yog hom tshwj xeeb ntawm cov hluav taws xob hluav taws xob hluav taws xob uas tsim los qhib thiab kaw sai. Tsis zoo li cov hluav taws xob hluav taws xob, uas tau tsim los "tawm mus" thiab nyob hauv lub xeev qhib, nws tuaj yeem hloov pauv sai sai ntawm lub xeev kaw, qhib thiab rov qab. Cov cuab yeej no tsom kom tsis txhob muaj kev cuam tshuam hauv lub network los ntawm kev ua rau muaj kev cuam tshuam ntev, los ntawm kev rov ua kom lub zog sai sai.

Auto recloser yog qhov kev teeb tsa tsis siv neeg ntawm lub tshuab hluav taws xob kom kaw tom qab qhib vim muaj kev tiv thaiv kev ua haujlwm. Nws yog siv nyob rau hauv ob qho tib si Nruab Nrab Voltage tis thiab High Voltage Transmission, txawm nyob rau hauv me ntsis txawv txoj kev. Distribution VCB siv standalone auto reclosers, xws li cov khoom Recloser, uas muaj ib tug kev tswj system, ib tug HV Reclosing Circuit Breaker thiab ib tug tej thaj chaw deb SCADA FTU.

Nws yog lub tshuab nqus tsev nqus lub neej ntev uas muab lub neej ua haujlwm ntawm ntau dua 100,000 (30,000 qhib / kaw) kev saib xyuas tsis pub ua haujlwm. Siv peb lub tsheb recloser ZW32 yuav ua rau muaj kev txuag nyiaj ntau los ntawm kev txo qis txij nkawm thiab ua kom lub txhab nyiaj ua haujlwm ntev tshaj plaws thiab tseem yuav txhim kho lub zog zoo. Nws ua raws li cov qauv ANSIC37.66 thiab Tuam Tshoj tus qauv. Qhov ntsuas hluav taws xob yog 33KV 35KV 36KV 40.5KV. Nws muaj motorized caij nplooj ntoos hlav hom & sib nqus actuator (nrog lub thawv tswj) hom.

◆ Siv tej yam kev mob

1.Ambient kub: -30 ℃ ~ + 60 ℃;

2.Altitude: ≤3000m;

3. Cua ceev: ≤34m/s;

4.Pollution qib: ≤IV.

5.Storage kub: -40 ℃ ~ + 85 ℃.

◆ Main Technical Parameters

TSIS MUAJ. Cov khoom Chav tsev Tus nqi
1 ntsuas voltage kV ua 40.5 ib
2 1min zog zaus withstand voltage kV ua 95
3 xob laim impulse withstand voltage kV ua 185
4 rated zaus Hz 50
5 ntsuas tam sim no A 630, 1250, 1600
6 rated luv Circuit Court breaking tam sim no kA 20, 25, 31.5 ib
7 rated luv Circuit Court ua tam sim no (peak)
kA 50, 63, 80
8 rated ncov tiv taus tam sim no kA 50, 63, 80
9 4s tiv tam sim no kA 20, 25, 31.5 ib
10 ntsuas kev ua haujlwm ib ntus S O-0.1s-CO-3s-CO-6S-60s rov qab
11 ntsuas luv Circuit Court tam sim no tawg tus lej sij hawm 30
12 neeg kho tshuab lub neej sij hawm 10000
13 mechanism tswj voltage IN AC / DC 220
14 Secondary Circuit Court 1min zog zaus withstand voltage kV ua 2
15 clearance nrug ntawm qhib hu mm 16 ± 1
16 hla kev mus ncig mm 4 ± 0.5
17 qhib ceev m/s 1.4-1.8 Nws
18 kaw ceev m/s 0.4-0.8 hli
19 hu rau lub sijhawm kaw bounce ms ≤ 5
20 peb theem qhib / kaw asynchronism ms ≤ 2
nees nkaum ib lub sijhawm kaw ms ≤100
nees nkaum ob lub sijhawm qhib ms ≤ 50
nees nkaum peb hnyav kg 270


  • Yav dhau los: