GRM6-40.5 Series Cubicle Hom Gas Insulated Switchgear

Lus piav qhia luv luv:


Product Detail

Khoom cim npe

Product Overview

GRM6-40.5 Series yog hom tshiab SF6 gas-insulated compact switchgears. Circuit Court breakers, disconnectors, thiab lwm yam yog nyob rau hauv 3 hli-thick hlau thawv ntim nrog ib tug tsawg-pressure SF6 roj. Yog li, cov khoom siv yog compact, txhim khu kev qha, thiab nyab xeeb; tsis muaj kev cuam tshuam ib puag ncig, kev saib xyuas dawb thiab kev pab lub neej ntev, thiab lwm yam.

GRM6-40.5 Series switchgears yog tsim rau kev tswj, kev tiv thaiv thiab kev saib xyuas ntawm 40.5 kV, peb-theem, ib tug busbar hluav taws xob system, lug siv nyob rau hauv generating tuam txhab uas muag, mining, thiab lwm yam.

 

Cov qauv siv tau

IEC 62271-1: High-voltage switchgear thiab controlgear-Tshooj 1: Cov lus qhia tshwj xeeb

IEC 62271-100 High-voltage switchgear thiab controlgear - Ntu 100: Hloov-tam sim no Circuit Court-breakers

IEC 62271-102 High-voltage switchgear thiab controlgear - Ntu 102: Kev hloov pauv tam sim no disconnectors thiab earthing keyboards

IEC 62271-103 High-voltage switchgear thiab controlgear - Ntu 103: Hloov rau cov ntsuas hluav taws xob siab tshaj 1 kV thiab mus txog thiab suav nrog 52 kV

IEC 62271-105 High-voltage switchgear thiab controlgear - Ntu 105: Hloov cov hloov tam sim no-fuse ua ke

IEC 62271-200: High-voltage switchgear thiab controlgear - Ntu 200: AC hlau-cuam tshuam switchgear thiab controlgear rau ntsuas voltage siab tshaj 1kV thiab mus txog thiab suav nrog 52 kV

IEC 60044-2: Instrument transformers - Ntu 2: Inductive voltage transformers

IEC 60044-1: Cov cuab yeej hloov pauv - Ntu 1: Tam sim no transformers

 

Siv Cov Cai

Qhov siab: ≤4000m★

ambient kub: -25 ℃ ~ + 40 ℃;

Cov huab cua txheeb ze: nruab nrab txhua hnub ≤95%, nruab nrab txhua hli ≤90%;

Seismic siv ≤8 chav kawm;

Qhov chaw tsis muaj hluav taws kub, tawg, muaj kab mob loj, tshuaj lom neeg corrosion thiab kev co hnyav.

Nco tseg★: Cov chaw tsim khoom yuav tsum tau sab laj ua ntej yog tias qhov chaw siab tshaj 1000 m thiaj li kho qhov nce siab.

Tus qauv naj npawb txhais

Qauv piav qhia

 

 

Main Technical Parameters

Tsis muaj.

Cov lus piav qhia

Chav tsev

Tus nqi

1

Rated voltage

kV ua

40.5 ib

2

Rated zaus

Hz

50

3

Rated nruam tam sim no

A

1250, 2500 Nws

4

Rated

rwb thaiv tsev

theem (Tawm,

Up,)

Hwj chim

zaus

tiv taus

voltage (Tawm)

(1 feeb)

Nruab nrab ntawm theem thiab theem mus rau lub ntiaj teb

kV ua

95

Hla ntawm kev sib cais

kV ua

118

Auxiliary and control circuits (Ua)

kV ua

2

xob laim

impulse

tiv taus

voltage (Up)

Nruab nrab ntawm theem thiab theem mus rau lub ntiaj teb

kV ua

185

Hla ntawm kev sib cais

kV ua

215

5

Rated luv-lub sij hawm tiv taus tam sim no (Ik / tk)

kA/s

25/4, 31.5/4

6

Rated ncov tiv taus tam sim no (Ip)

kA

63,80 ib

7

Rated luv-circuit breaking tam sim no (Isc)

kA

25 Ib., 31.5

8

Rated short-circuit ua tam sim no

kA

63,80 ib

9

Circuit Court breaker hluav taws xob endurance

/

30x ua

10

Rated ua haujlwm ib ntus.

/

O-0.3s-CO-180s-CO

11

Mechanical endurance

Circuit Court breaker

Ops

20000

Disconnectors/Earthing keyboards

Ops

5000

12

Kev tiv thaiv ntawm Circuit Court

1250 A

≤120

2500 A

≤80

13

Rated gas- filling siab (qhov siab ntawm 20 ° C)

MPa

0.02 ib

14

Txhua xyoo leakage rate (kwv yees siab)

/

≤0.01%

15

Kev cais nruab nrab

/

SF 6

16

 

Qib kev tiv thaiv

(IP)

Kev cais nruab nrab

/

IP2XC

Roj tank

/

IP67

Npog

/

IP41

Npog

/

IK 10

17

Classification IAC thiab Internal IAC

/

A-FLR, 31.5 kA 1s

 

Daim ntawv dimension

DIMENSION

 


  • Yav dhau los:
  • Tom ntej: