FN7-12 yog hom tshiab ntawm huab cua sab hauv tsev high-voltage load so hloov. Nws yog haum rau AC 50Hz, nyob voltage 12kV peb-theem AC fais fab system, raws li qhov tawg load tam sim no thiab kaw luv-circuit tam sim no.
Hom lus piav qhia
Cov xwm txheej ua haujlwm
● Ambient kub: -25 ° C ~ 40 ° C;
● Qhov siab:
● txheeb ze av noo: nruab nrab txhua hnub
● Yuav tsum tsis muaj corrosive, combustion thiab explosion gas los yog vapor ntawm qhov chaw;
● Tsis tshua muaj kev vibration hnyav.
Technical Parameters
Cov ntsiab lus tseem ceeb ceeb toom: (-) tsis muaj (A) nrog Table 1
Lub npe | Hom | Qauv | DS | DX | L | R | DA | F |
Lub ntiaj teb hloov hauv inlet | Lub ntiaj teb hloov ntawm qhov hluav taws xob | Interlock ntaus ntawv | Fuse | Striker fuse | Hluav taws xob qhib ntaus ntawv | |||
Load break switch | Tsis muaj tripper | FN7-12 | - | - | - | - | - | - |
FN7-12 DSL | A | - | A | - | - | - | ||
FN7-12DXL | - | A | A | - | - | - | ||
FN7-12R | - | - | - | A | - | - | ||
FN7-12 DSLR | A | - | A | A | - | - | ||
FN7-12DXLR | - | A | A | A | - | - | ||
Nrog striking tripper | FN7-12RA | - | - | - | - | A | - | |
FN7-12 UA | - | - | - | - | A | A | ||
FN7-12DXLRA | - | A | A | - | A | - | ||
FN7-12DXLRAF | - | A | A | - | A | A |
Rated tsis Table 2
Rated voltage kV | Max. zog kV | Rated tam sim no A | 1min fais fab zaus tiv taus voltage kV | 4s thermal stability tam sim no (RMS) kA | Dynamic stability tam sim no (peak) kA | Short circuit ua tam sim no kA | Rated tam sim no A | Rated hloov tam sim no A |
12 | 12 | 400 | 42/48 ib | 12.5 ib | 31.5 ib | 31.5 ib | 400 | 1000 |
630 | 42/48 ib | 20 | 50 | 50 | 630 | 1000 |
Rated parameters ntawm fUse Table 3
Qauv | Rated voltage kV | Rated tam sim no A | Rated tam sim no ntawm fuse |
SDLA*J | 12 | 40 | 6, 3, 10, 16, 20, 25, 31.5, 40 |
SFLA*J | 12 | 100 | 50, 63, 71, 80, 100 |
GLASS*J | 12 | 125 | 125 |
A*: nrog tus ntaus.
General Structure Drawing thiab Installation Loj (unit mm)
1. Arc Extinguishing Riam 2. Arc Contact Part thiab Arc Extinguishing Chamber 3. Insulator 4. Base
5. Dynamic Contact Riam 6. Static Contact Riam 7. Caij nplooj ntoos hlav zog cia khoom (sab hauv lub tes tsho loj axis) 8. Main riam tig caj npab
Kos duab 1 FN7-12 load hloov cov qauv thiab kev teeb tsa loj
1.Arc Extinguishing Riam 2.Arc Contact Part thiab Arc Extinguishing Chamber 3. Insulator 4. Base
5. Dynamic Contact Riam6.Static Contact Riam 7. Caij nplooj ntoos hlav lub zog cia khoom (hauv lub tes tsho loj axis)
8. Earthing Riam 9. Main riam kaw tig caj npab 10. Earthing riam kaw tig caj npab
Kos duab 2 FN7-12DXL load hloov cov qauv thiab installation loj
1.Arc Extinguishing Riam 2.Arc Contact Part thiab Arc Extinguishing Chamber 3. Insulator 4. Earthing riam
5. Base 6. Dynamic Contact Riam 7 * Static Contact Rife 8. Fuse 9 * Caij nplooj ntoos hlav zog cia khoom (hauv lub tes tsho loj)
10. Earthing zog-storage caij nplooj ntoos hlav 11. Interlock ntaus ntawv 12. Lub ntsiab riam kaw&opeing tig caj npab
13. Earthing riam kaw & qhib tig caj npab
Kos duab 3 FN7-12DXLR cais hom load hloov cov qauv thiab qhov loj me me
1.Arc Extinguishing Riam 2.Arc Contact Part thiab Arc Extinguishing Chamber 3. Insulator 4. Base
5. Dynamic Contact Riam 6. Static Contact Riam 7. Caij nplooj ntoos hlav zog cia khoom (hauv lub tes tsho loj axis)
8. Fuse 9. Lub ntsiab riam kaw & qhib tig caj npab
Kos duab 4 FN7-12R cais hom load hloov cov qauv thiab qhov loj me me
1 .Arc Extinguishing Riam 2.Arc Contact Part thiab Arc Extinguishing Chamber 3. Impact type Fuse4.Insulator Base 5. Earthing riam
6. Base 7. Dynamic Contact Rife 8. Main riam kaw lub caij nplooj ntoos hlav 9. Static Contact Rife 10. Earthing zog-storage caij nplooj ntoos hlav
11. Cov riam tseem ceeb qhib lub caij nplooj ntoos hlav 12. Cov cuab yeej sib cuam tshuam 13. Lub ntsiab riam kaw & qhib tig caj npab m 14. Lub ntiaj teb riam kaw & qhib tig caj npab
Kos duab 5 FN7-12DXLRA integrated type load switch outline and installation size
1.Arc Extinguishing Riam 2. Arc Contact Part thiab Arc Extinguishing Chamber
3. Insulator 4. Base 5. Dynamic Contact Riam 6. Static Contact Riam
7. Lub caij nplooj ntoos hlav lub zog cia khoom (hauv lub tes tsho loj axis) 8. Phaj
Kos duab 6 FN7-12C load hloov cov qauv thiab kev teeb tsa loj
1.Arc Extinguishing Riam 2. Arc Contact Part thiab Arc Extinguishing Chamber
3. Insulator 4. Base5.Dynamic Contact Riam 6. Static Contact Riam
7. Lub caij nplooj ntoos hlav lub zog cia khoom (hauv lub tes tsho loj axis) 8. Fuse 9. Phaj
Kos duab 7 FN7-12CR cais hom load hloov cov qauv thiab qhov loj me me
1.Arc Extinguishing Riam 2. Arc Contact Part thiab Arc Extinguishing Chamber 3. Impact type fuse 4. Earthling riam
5. Insulator6.Base 7. Lub ntsiab riam kaw lub caij nplooj ntoos hlav 8. Dynamic Contact Riam 9. Static Contact Rife
10.Earthing zog cia caij nplooj ntoos hlav 11. Lub ntsiab riam qhib caij nplooj ntoos hlav 12.Plate 13. Kos duab 11
Kos duab 8 FN7-12CDXLRA integrated type load switch outline and installation size